Copyright © 2004, Tjernlund Products, Inc. All rights reserved P/N 8504102
OWNER INSTRUCTIONS, DO NOT DESTROY
Recognize this symbol as an indication of important Safety Information!
NOTE: FLUE GAS TEMPERATURES MUST NOT EXCEED
650
o
F AT VENT SYSTEM INLET.
THESE INSTRUCTIONS ARE INTENDED AS AN AID TO QUALIFIED, LICENSED
SERVICE PERSONNEL FOR PROPER INSTALLATION, ADJUSTMENT AND
OPERATION OF THIS UNIT. READ THESE INSTRUCTIONS THOROUGHLY
BEFORE ATTEMPTING INSTALLATION OR OPERATION. FAILURE TO FOLLOW
THESE INSTRUCTIONS MAY RESULT IN IMPROPER INSTALLATION, ADJUST-
MENT, SERVICE OR MAINTENANCE POSSIBLY RESULTING IN FIRE, ELECTRI-
CAL SHOCK, CARBON MONOXIDE POISONING, EXPLOSION, OR PERSONAL
INJURY OR PROPERTY DAMAGE.
!
DO NOT DESTROY. PLEASE READ CAREFULLY AND
KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
MODEL SS1
INSTALLATION INSTRUCTIONS
REV. C 02/04
TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com
INCLUDES NEW UC1
UNIVERSAL CONTROL
VERSION
X.04
Vista de página 0
1 2 3 4 5 6 ... 23 24

Resumo do Conteúdo

Página 1 - INSTALLATION INSTRUCTIONS

Copyright © 2004, Tjernlund Products, Inc. All rights reserved P/N 8504102OWNER INSTRUCTIONS, DO NOT DESTROYRecognize this symbol as an indication of

Página 2

NOTCH BRACINGIt is recommended and local codes may dictate that the joist be reinforced as outlined below. Bracing of the rim joist is not necessary.

Página 3 - FRONT VIEW

10INSTALLATION OF VENT PIPE If installing the SideShot Vent System on an oil or gas appliance which is not equipped with a draft hood or draft diverte

Página 4

114. Using a tube cutter, cut the sensing tube 2" from the elbow directed at the vent pipe inlet collar, (See Diagram L). Discard the cut off se

Página 5

ELECTRICAL WIRING All wiring from the SS1 to the appliance must be appropriate Class 1 wiring as follows: installed in rigid metal conduit, intermedia

Página 6 - 1 9

13SIDESHOT WITH INTEGRAL UC1 UNIVERSAL CONTROL CONNECTED TO A HONEYWELL R8184 SERIES OR EQUIVALENT PRIMARY CONTROL50/60 HzRWHITEORANGEBLACKHONEYWELLR8

Página 7

14SIDESHOT WITH INTEGRAL UC1 UNIVERSAL CONTROL CONNECTED WITH AN AQUASTATXNRUNIVERSAL CONTROLLERLINE VOLTAGE OIL BURNERPRIMARY CONTROL, BURNERL1NXLJ1J

Página 8

15SIDESHOT WITH INTEGRAL UC1 UNIVERSAL CONTROL CONNECTED WITH A HONEYWELL R8184 SERIES OR EQUIVALENT PRIMARY CONTROL AND A BURNER MOTOR POST-PURGE 1.

Página 9

16SIDESHOT WITH INTEGRAL UC1 CONTROL CONNECTED WITH A 24 VAC ELECTRONIC IGNITION MODULEXNRUNIVERSAL CONTROLLERD/N 9183046-8115 VAC24 VACLEGEND:HONEYWE

Página 10

DRAFT ADJUSTMENT PROCEDURE17SIDESHOT WITH INTEGRAL UC1 UNIVERSAL CONTROL CONNECTED WITH A 24 OR 115 VAC STANDING PILOT115V24VDRYOF FURNACE/BOILERINTER

Página 11

DRAFT ADJUSTMENT PROCEDURE FOR OIL EQUIPMENTThe SideShot Vent system will properly vent a wide range of BTU/hr. input capacities. To compensate for d

Página 12

1Tjernlund Products welcomes your comments and questions. Address all correspondence to:Customer Service • Tjernlund Products, Inc. • 1601 Ninth Stre

Página 13 - TJERNLUND

IMPORTANT:The following paragraph describes the initial draft adjustment. It may be necessary to make a slight readjustment to compensatefor various

Página 14 - UNIVERSAL CONTROLLER

TROUBLESHOOTING OIL ODORSMany problems can be eliminated quite easily by having the equipment properly set up by a professional oil-heat service contr

Página 15 - D/N 9183046-3

LED FAULT INDICATORSFault conditions are indicated by counting the number of times LED #4 (Red) flashes.LED #4 Flashes 2 Times Fan Prover was in elect

Página 16

Voltage should be the same in both cases, if not rewire per appropriate diagram or confirm burner control(s) are functioning prop-erly. NOTE: If a d

Página 17 - D/N 9183046-5

23WHEEL REPLACEMENT (DIAGRAM N)1. Loosen set screw from wheel hub by using a 5/32” allen wrench.2. Twist wheel to loosen and pull off of motor shaft.

Página 18

2SPECIFICATIONSMotor: 115/1/60, 3300 RPM, 212 watts, 2.28 FLAFan Proving Switch: Non-adjustable set point of -.05" W.C.High Limit: Manual reset

Página 19

CAUTIONSThe SS1 must be installed by a qualified installer (an individual properly licensed and/or trained) in accordance with all local codes or, in

Página 20

SS1 WITH INTEGRAL UC1 UNIVERSAL CONTROL BOARD FEATURES# 1. Power supplied by board. Do not supply power to this area or control damage may result.# 2

Página 21

LED FAULT INDICATORS Fault conditions are indicated by counting the number of times LED #4 (Red) flashes.LED #4 Flashes 2 Times Fan Prover was in elec

Página 22

PLENUM AND VENT HOOD CLEARANCE FROM COMBUSTIBLESWith an inlet flue gas temperature of 650oF or below, the SS1 has been Listed for the following cleara

Página 23

INSTALLATIONTools required:• Reciprocating Saw • 1/2", 7/16",5/8" Wrench• Drill and 1/8", 1/4", 1/2" Bits • 1/4" Ma

Página 24

9. Connect the Plenum to the Vent Hood of the SideShot following the steps on pages 8, 9 and 10. 10. After the SideShot is completely installed, apply